Easily adjustable opening&closing speed, opening angle,hold open time by hand programmer.
The normal motion:
Opening detection signal ON - Open the door - Opening braking- Opening damping -Opening hold time - Closing the door Closing braking -Closing damping -Stop applying closing force to the door
00.Opening speed, 0-99 adjustable
01.closing speed, 0-99 adjustable
02.The speed of damping opening, 1-10 adjustable
03.The speed of damping closing, 1-10 adjustable
04.Opening damping distance, 10-50 adjustable
05.Closing damping distance, 10-50 adjustable
06. Hold-open time: The time from the door opening destination till the door begin to close, 0-10s adjustable
07.Delay-open time: delay opening time 0-3s adjustable,
specially supply time for electro lock to lock or unlock which is helpful to avoid damage to drop bolt lock.
08. Opening direction
09.Fire signal open/close: It is only used when connected with fire alarm system.
10.Induction: 0-1 0 is once induction, For example: The door will open and then close automatically when you press the push button once. 1 is twice induction, For example: The door will open automatically when you press the push button once, and you need to press the push button again to make the door close automatically.
11. The braking force when the door being fully opened and closed, 0-99 adjustable
12. Minimum Force of Slow Speed: Adjust the
13. Locking force 0-30: The force to open the door manually when the door is closing
Operation Procedure:
Activated by the signals from external control device, unlock→open→damping action&stop→hold open→close→damping action&stop→lock and seal.
1.Opening speed, 10-100 adjustable
2.closing speed, 10-100 adjustable
3.The speed of damping opening, 1-10 adjustable
4.The speed of damping closing, 1-10 adjustable
5.Opening damping distance, 1-60 adjustable
6.Closing damping distance, 1-60 adjustable
7. The time from the door opening destination till the door
begin to close, 0-120s adjustable
8.Delay-open time: delay opening time 0-3s adjustable, specially supply time for electro lock to lock or unlock which is helpful to avoid damage to drop bolt lock.
9. Opening direction (Left or Right)
A. Fire signal open/close: It is only used when connected with fire alarm system.
B. Opening angle adjust: 30-200 adjustable. The digital angle is not the door opening angle, but the driving axis turning angle; the door opening angle features different subject to the sliding arm or articulated arm. Users can adjust the digits referring to the real door opening angle.
C. Locking force 0-30: The force to open the door manually when the door is closing
D. The braking force when the door being fully opened, 0-60 adjustable
E. The braking force when the door being fully closed, 0-60 adjustable